EAM aluminum

SystemEAM
Atoms101
Runs639
Cap—1

1 The problem file does not state a cap.

The main metric is Barrier force calls. Scoring rules.

Charts

Success rate on EAM aluminum, in rank order. The rate is the share of runs that finished. 2 ranked rows did not record a success rate and are not drawn.
Success rate on EAM aluminum, in rank order. The rate is the share of runs that finished. 2 ranked rows did not record a success rate and are not drawn. PDF.
Dolan-Moré profile for Minimum mode on EAM aluminum. The curve is the fraction of starts whose cost is at most tau times the best finite cost in this family. Tau is 1, 2, 4, 8, and 16. An unsolved start stays in the denominator and does not cross a finite tau. Dolan, E. D. and Moré, J. J., Math. Program. 91:201-213, 2002.
Dolan-Moré profile for Minimum mode on EAM aluminum. The curve is the fraction of starts whose cost is at most tau times the best finite cost in this family. Tau is 1, 2, 4, 8, and 16. An unsolved start stays in the denominator and does not cross a finite tau. Dolan, E. D. and Moré, J. J., Math. Program. 91:201-213, 2002. PDF.
Force calls on each recorded start for EAM aluminum. The box is the quartiles of those counts. A blue point is a success and a vermillion cross is a recorded failure (0). The horizontal position is the recorded count. The vertical offset only keeps marks from covering one another.
Force calls on each recorded start for EAM aluminum. The box is the quartiles of those counts. A blue point is a success and a vermillion cross is a recorded failure (0). The horizontal position is the recorded count. The vertical offset only keeps marks from covering one another. PDF.
Performance profile for EAM aluminum00.51124816Cost ratioFraction of startsEON (SVN r2549) (r2549) · Dimer-CG rotation: max=50 tol=1eOn (develop 500350d9) (500350d9) · Dimer-CG rotation: max=50 tol=1
Performance profile. Higher means more starts solved within that cost ratio.
  • EON (SVN r2549) (r2549) · Dimer-CG rotation: max=50 tol=1
  • eOn (develop 500350d9) (500350d9) · Dimer-CG rotation: max=50 tol=1
Cost distribution for EAM aluminum0121070 to 24970: 124970 to 28870: 12107028870
Cost distribution of 2 ranked rows. Linear bins, from 21070 to 28870. 2 ranked rows have no cost on this scale and are left off the chart.

Performance profile SVG Cost and success SVG

Performance profile for EAM aluminum
Performance profile. Select the plot for the full SVG.
Cost and success for EAM aluminum
Cost and success. Select the plot for the full SVG.
Best cost for AlAl10⁴10⁵cost (force calls, log scale)Eon svn: 21070Eon svn21070
A shorter bar is a lower cost on a log scale shared by the codes of this problem.

Leaderboard

A shorter bar is a lower cost on the log scale for that problem. Select a column heading to sort.
RankCodeBestMedianSuccessPAR-2
1 Eon svn 21070 24970 —1 —2

1 A dash in the success rate means that row did not record one.

2 A dash in PAR-2 means that row has no PAR-2 score.

The tables below list every ranked row, by method family and overall.

A run short of the full set, or a run that is not the stock method, stays off the ranked table.

These archived rows rank on the value each one published, which leaves out any failure. The failure rule has no score for them, for the reason given with each.

  • eOn (r2006) · Dimer-CG rotation: max=10 tol=1 (the entry records no failure count)
  • eOn (r2006) · Dimer-CG rotation: max=50 tol=1 (the entry records no failure count)

Minimum mode

Minimum mode. One row is one code, one version, and one method. A lower cost is better. PAR-2 counts a finished run as the calls it used and a failed run as twice the cap. An archived row shows the average it published, and its PAR-2 applies that rule to the failures the entry records. Hessians is the mean analytic Hessian count. FD calls is that count times one force call per coordinate.
RankRowCostUnitHessiansFD callsRuns
1eOn (r2006) · Dimer-CG rotation: max=10 tol=121070force calls00432
2eOn (r2006) · Dimer-CG rotation: max=50 tol=128870force calls00639
3EON (SVN r2549) (r2549) · Dimer-CG rotation: max=50 tol=1force calls00639
4eOn (develop 500350d9) (500350d9) · Dimer-CG rotation: max=50 tol=1force calls00639

Overall

One row is one code, one version, and one method. A lower cost is better. PAR-2 counts a finished run as the calls it used and a failed run as twice the cap. An archived row shows the average it published, and its PAR-2 applies that rule to the failures the entry records. Hessians is the mean analytic Hessian count. FD calls is that count times one force call per coordinate.
RowFamilyFamily rankUnitPAR-2PublishedMedian callsMean callsHessiansFD callsFailuresRuns
eOn (r2006) · Dimer-CG rotation: max=10 tol=1Minimum mode1force calls210702107000not recorded432
eOn (r2006) · Dimer-CG rotation: max=50 tol=1Minimum mode2force calls288702887000not recorded639
EON (SVN r2549) (r2549) · Dimer-CG rotation: max=50 tol=1Minimum mode3force calls3599845626.900crash 0, divergence 0, cap 0, wrong_stationary 0639
eOn (develop 500350d9) (500350d9) · Dimer-CG rotation: max=50 tol=1Minimum mode4force calls4182048128.800crash 0, divergence 0, cap 0, wrong_stationary 0639